Skip to content
Snippets Groups Projects
Select Git revision
  • ad1a0a5fb4256be1d1d4476cf5486cfa0a55aae5
  • master default
  • trunk
  • RELEASE_6_5_DRIVEDB
  • RELEASE_6_6_DRIVEDB
  • RELEASE_7_0_DRIVEDB
  • RELEASE_7_2_DRIVEDB
  • RELEASE_7_3_DRIVEDB
  • RELEASE_6_0_DRIVEDB
  • RELEASE_6_1_DRIVEDB
  • RELEASE_6_2_DRIVEDB
  • RELEASE_6_3_DRIVEDB
  • RELEASE_6_4_DRIVEDB
  • tags/RELEASE_7_4
  • tags/RELEASE_7_3
  • RELEASE_5_41_DRIVEDB
  • RELEASE_5_42_DRIVEDB
  • RELEASE_5_43_DRIVEDB
  • tags/RELEASE_7_2
  • tags/RELEASE_7_1
  • tags/RELEASE_7_0
  • RELEASE_5_40_DRIVEDB
22 results

MAXTOR-1.txt

Blame
  • user avatar
    pervalidus authored
    .html -> /examples/.txt
    
    
    git-svn-id: https://smartmontools.svn.sourceforge.net/svnroot/smartmontools/trunk@269 4ea69e1a-61f1-4043-bf83-b5c94c648137
    3c0831ed
    History
    MAXTOR-1.txt 7.11 KiB
    smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
    Home page is http://smartmontools.sourceforge.net/
    
    === START OF INFORMATION SECTION ===
    Device Model:     MAXTOR 4K080H4                          
    Serial Number:    674119123435        
    Firmware Version: A08.1500
    ATA Version is:   5
    ATA Standard is:  ATA/ATAPI-5 T13 1321D revision 1
    SMART support is: Available - device has SMART capability.
    SMART support is: Enabled
    
    === START OF READ SMART DATA SECTION ===
    SMART overall-health self-assessment test result: FAILED!
    Drive failure expected in less than 24 hours. SAVE ALL DATA.
    See vendor-specific Attribute list for failed Attributes.
    
    General SMART Values:
    Off-line data collection status: (0x04)	Offline data collection activity was 
    					suspended by an interrupting command from host.
    Self-test execution status:      (  89)	The previous self-test completed having
    					the electrical element of the test
    					failed.
    Total time to complete off-line 
    data collection: 		 (2536) seconds.
    Offline data collection
    capabilities: 			 (0x1b) SMART execute Offline immediate.
    					Automatic timer ON/OFF support.
    					Suspend Offline collection upon new
    					command.
    					Offline surface scan supported.
    					Self-test supported.
    SMART capabilities:            (0x0003)	Saves SMART data before entering
    					power-saving mode.
    					Supports SMART auto save timer.
    Error logging capability:        (0x01)	Error logging supported.
    Short self-test routine 
    recommended polling time: 	 (   2) minutes.
    Extended self-test routine 
    recommended polling time: 	 (  50) minutes.
    
    SMART Attributes Data Structure revision number: 11
    Vendor Specific SMART Attributes with Thresholds:
    ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE     WHEN_FAILED RAW_VALUE
      1 Raw_Read_Error_Rate     0x0029   100   253   020    Pre-fail     -       0
      3 Spin_Up_Time            0x0027   074   074   020    Pre-fail     -       3294
      4 Start_Stop_Count        0x0032   100   100   008    Old_age      -       32
      5 Reallocated_Sector_Ct   0x0033   001   001   020    Pre-fail FAILING_NOW 499
      7 Seek_Error_Rate         0x000b   100   001   023    Pre-fail In_the_past 0
      9 Power_On_Hours          0x0012   086   086   001    Old_age      -       9812
     10 Spin_Retry_Count        0x0026   100   100   000    Old_age      -       0
     11 Calibration_Retry_Count 0x0013   100   100   020    Pre-fail     -       0
     12 Power_Cycle_Count       0x0032   100   100   008    Old_age      -       32
     13 Read_Soft_Error_Rate    0x000b   100   001   023    Pre-fail In_the_past 0
    194 Temperature_Centigrade  0x0022   091   086   042    Old_age      -       24
    195 Hardware_ECC_Recovered  0x001a   006   004   000    Old_age      -       417912090
    196 Reallocated_Event_Count 0x0010   100   100   020    Old_age      -       0
    197 Current_Pending_Sector  0x0032   033   032   020    Old_age      -       338
    198 Offline_Uncorrectable   0x0010   100   100   000    Old_age      -       0
    199 UDMA_CRC_Error_Count    0x001a   200   200   000    Old_age      -       0
    
    SMART Error Log Version: 1
    ATA Error Count: 20255 (device log contains only the most recent five errors)
    	DCR = Device Control Register
    	FR  = Features Register
    	SC  = Sector Count Register
    	SN  = Sector Number Register
    	CL  = Cylinder Low Register
    	CH  = Cylinder High Register
    	D/H = Device/Head Register
    	CR  = Content written to Command Register
    	ER  = Error register
    	STA = Status register
    Timestamp is seconds since the previous disk power-on.
    Note: timestamp "wraps" after 2^32 msec = 49.710 days.
    
    Error 1 occurred at disk power-on lifetime: 9574 hours
    When the command that caused the error occurred, the device was in a vendor specific or reserved state.
    After command completion occurred, registers were:
    ER:40 SC:60 SN:b8 CL:c6 CH:02 D/H:e5 ST:d1
    Sequence of commands leading to the command that caused the error were:
    DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
     02   05   60   b8   c6   02    e5   c4     474.857
     02   05   f8   20   c6   02    e5   c4     470.748
     02   05   08   18   c6   02    e5   c4     470.746
     00   00   f8   20   c5   02    e5   c4     470.732
     00   00   08   18   c5   02    e5   c4     470.730
    
    Error 2 occurred at disk power-on lifetime: 9574 hours
    When the command that caused the error occurred, the device was in a vendor specific or reserved state.
    After command completion occurred, registers were:
    ER:40 SC:68 SN:b0 CL:c6 CH:02 D/H:e5 ST:d1
    Sequence of commands leading to the command that caused the error were:
    DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
     02   05   f8   20   c6   02    e5   c4     470.748
     02   05   08   18   c6   02    e5   c4     470.746
     00   00   f8   20   c5   02    e5   c4     470.732
     00   00   08   18   c5   02    e5   c4     470.730
     02   05   f8   20   c4   02    e5   c4     470.717
    
    Error 3 occurred at disk power-on lifetime: 9574 hours
    When the command that caused the error occurred, the device was in a vendor specific or reserved state.
    After command completion occurred, registers were:
    ER:40 SC:08 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
    Sequence of commands leading to the command that caused the error were:
    DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
     0e   05   08   c0   3e   0e    e5   c4     181.677
     d0   04   08   b0   67   d0    e4   c5     181.651
     0e   05   08   a0   45   0e    e5   c4     181.646
     0e   05   80   20   43   0e    e5   c4     181.635
     0e   05   80   20   41   0e    e5   c4     181.622
    
    Error 4 occurred at disk power-on lifetime: 9574 hours
    When the command that caused the error occurred, the device was in a vendor specific or reserved state.
    After command completion occurred, registers were:
    ER:40 SC:60 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
    Sequence of commands leading to the command that caused the error were:
    DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
     0e   05   80   a0   3e   0e    e5   c4     172.530
     0e   05   80   20   3d   0e    e5   c4     172.335
     0e   05   80   20   3c   0e    e5   c4     164.744
     0e   05   10   10   3b   0e    e5   c4     164.736
     0e   05   f8   18   3a   0e    e5   c4     157.202
    
    Error 5 occurred at disk power-on lifetime: 9574 hours
    When the command that caused the error occurred, the device was in a vendor specific or reserved state.
    After command completion occurred, registers were:
    ER:40 SC:c0 SN:18 CL:04 CH:d3 D/H:e4 ST:d1
    Sequence of commands leading to the command that caused the error were:
    DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
     d3   04   c0   18   04   d3    e4   c4     502.837
     d3   04   f8   e0   03   d3    e4   c4     498.739
     d3   04   f8   e8   02   d3    e4   c4     498.716
     55   01   c8   90   70   55    e1   c4     498.705
     55   01   38   48   70   55    e1   c4     498.680
    
    SMART Self-test log, version number 1
    Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
    # 1  Short off-line      Completed: electrical failure 90%      9786         
    # 2  Extended captive    Completed: servo/seek failure 90%      9676         0x04b7ed3d
    # 3  Extended captive    Completed                     00%      9575         
    # 4  Extended off-line   Completed                     00%      9432         
    # 5  Extended off-line   Completed                     00%      9415