[root/]# smartctl -v 9,seconds -v 200,writeerrorcount /dev/hda
smartctl version 5.1-18 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: FUJITSU MHR2040AT
Serial Number: NJ41T291391J
Firmware Version: 40BA
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 1
Local Time is: Thu Sep 4 22:18:48 2003 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Auto Off-line Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 468) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail Always - 52685626284
2 Throughput_Performance 0x0005 100 100 020 Pre-fail Offline - 0
3 Spin_Up_Time 0x0003 093 093 025 Pre-fail Always - 24065
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 160
5 Reallocated_Sector_Ct 0x0033 099 099 024 Pre-fail Always - 31
7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 131071
8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0
9 Power_On_Seconds 0x0032 092 092 000 Old_age Always - 1335h+10m+34s
10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 150
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 7
193 Load_Cycle_Count 0x0032 074 074 000 Old_age Always - 95890
194 Temperature_Celsius 0x0022 090 100 000 Old_age Always - 57
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 10141348
196 Reallocated_Event_Count 0x0032 099 099 000 Old_age Always - 30
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Write_Error_Count 0x000f 036 033 060 Pre-fail Always FAILING_NOW 2883583
203 Run_Out_Cancel 0x0002 091 091 000 Old_age Always - 2589872160305
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged
smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: FUJITSU MHR2020AT
Serial Number: NJ13T2215TUH
Firmware Version: 30B8
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 1
Local Time is: Sun Aug 15 13:21:33 2004 MEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 105) The previous self-test completed having
the servo (and/or seek) element of the
test failed.
Total time to complete Offline
data collection: ( 234) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 30) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 007 001 046 Pre-fail Always FAILING_NOW 154618843423
2 Throughput_Performance 0x0005 100 100 020 Pre-fail Offline - 145
3 Spin_Up_Time 0x0003 094 083 025 Pre-fail Always - 24321
4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 1887
5 Reallocated_Sector_Ct 0x0033 099 099 024 Pre-fail Always - 1
7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 458751
8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0
9 Power_On_Seconds 0x0032 088 088 000 Old_age Always - 1819h+16m+52s
10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 091 091 000 Old_age Always - 1467
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 44
193 Load_Cycle_Count 0x0032 086 086 000 Old_age Always - 49810
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 32
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 1221
196 Reallocated_Event_Count 0x0032 099 099 000 Old_age Always - 1
197 Current_Pending_Sector 0x0012 001 001 000 Old_age Always - 10
198 Offline_Uncorrectable 0x0010 092 092 000 Old_age Offline - 17
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always - 393215
203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 429515210380
SMART Error Log Version: 1
ATA Error Count: 6861 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 6861 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 90 78 16 51 f0 00 08:22:32.857 READ DMA EXT
Error 6860 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 98 70 16 51 f0 00 08:22:27.700 READ DMA EXT
Error 6859 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 a0 68 16 51 f0 00 08:22:22.558 READ DMA EXT
Error 6858 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 a8 60 16 51 f0 00 08:22:17.458 READ DMA EXT
Error 6857 occurred at disk power-on lifetime: 1818 hours (75 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 8b 7d 16 51 f0 Error: UNC 139 sectors at LBA = 0x0051167d = 5314173
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 b0 58 16 51 f0 00 08:22:12.558 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: servo/seek failure 90% 1819 -
# 2 Extended offline Completed: servo/seek failure 90% 1816 -
Device does not support Selective Self Tests/Logging
smartctl version 5.30 Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: HITACHI_DK23AA-12B
Serial Number: xxxxxx
Firmware Version: 00XDA0B6
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
Local Time is: Sat Apr 24 17:19:58 2004 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity was
never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (1110) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 19) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000d 099 099 050 Pre-fail Offline - 68719476757
4 Start_Stop_Count 0x0032 097 097 050 Old_age Always - 3259
5 Reallocated_Sector_Ct 0x0033 001 001 010 Pre-fail Always FAILING_NOW 1876
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 760
9 Power_On_Hours 0x0032 090 090 060 Old_age Always - 21783
10 Spin_Retry_Count 0x0013 100 100 050 Pre-fail Always - 0
196 Reallocated_Event_Count 0x0032 001 001 001 Old_age Always FAILING_NOW 254
197 Current_Pending_Sector 0x0032 097 093 001 Old_age Always - 3
198 Offline_Uncorrectable 0x0010 100 100 001 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
221 G-Sense_Error_Rate 0x000a 100 100 050 Old_age Always - 42
223 Load_Retry_Count 0x0012 100 100 050 Old_age Always - 149
225 Load_Cycle_Count 0x0032 050 050 050 Old_age Always FAILING_NOW 5110222858734
250 Read_Error_Retry_Rate 0x000a 090 001 050 Old_age Always In_the_past 103
SMART Error Log Version: 1
ATA Error Count: 1151 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Timestamp = decimal seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1151 occurred at disk power-on lifetime: 5445 hours
When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 01 01 4f c2 e0 Error: obs
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
b0 d5 01 01 4f c2 e0 00 46273.155 SMART READ LOG
b0 d1 01 01 4f c2 e0 00 46273.138 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 d0 01 00 4f c2 e0 00 46273.009 SMART READ DATA
b0 da 00 00 4f c2 a0 00 46272.881 SMART RETURN STATUS
b0 da 00 00 4f c2 e0 00 46272.760 SMART RETURN STATUS
Error 1150 occurred at disk power-on lifetime: 5354 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 01 56 36 54 e1 Error: AMNF 1 sectors at LBA = 0x01543656 = 22296150
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 80 d7 35 54 e1 00 1517.332 READ DMA
c8 00 80 57 35 54 e1 00 1517.329 READ DMA
ca 00 08 67 1d cb e0 00 1516.014 WRITE DMA
ca 00 30 37 1d cb e0 00 1515.992 WRITE DMA
ca 00 10 2f e0 ca e0 00 1515.874 WRITE DMA
Error 1149 occurred at disk power-on lifetime: 5352 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 0c bb c5 57 e1 Error: AMNF 12 sectors at LBA = 0x0157c5bb = 22529467
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 20 a7 c5 57 e1 00 380.146 READ DMA
10 00 3f 00 00 00 e0 00 380.146 RECALIBRATE [OBS-4]
c8 00 20 a7 c5 57 e1 00 377.932 READ DMA
c8 00 20 a7 c5 57 e1 00 373.729 READ DMA
c8 00 80 6f 41 5f e1 00 371.776 READ DMA
Error 1148 occurred at disk power-on lifetime: 5352 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 0c bb c5 57 e1 Error: AMNF 12 sectors at LBA = 0x0157c5bb = 22529467
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 20 a7 c5 57 e1 00 377.932 READ DMA
c8 00 20 a7 c5 57 e1 00 373.729 READ DMA
c8 00 80 6f 41 5f e1 00 371.776 READ DMA
c8 00 80 ef 40 5f e1 00 371.742 READ DMA
ca 00 08 57 1f cb e0 00 371.291 WRITE DMA
Error 1147 occurred at disk power-on lifetime: 5352 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
01 51 0c bb c5 57 e1 Error: AMNF 12 sectors at LBA = 0x0157c5bb = 22529467
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 20 a7 c5 57 e1 00 373.729 READ DMA
c8 00 80 6f 41 5f e1 00 371.776 READ DMA
c8 00 80 ef 40 5f e1 00 371.742 READ DMA
ca 00 08 57 1f cb e0 00 371.291 WRITE DMA
ca 00 10 47 1f cb e0 00 371.262 WRITE DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 5445 -
# 2 Short offline Completed without error 00% 5445 -
# 3 Short offline Aborted by host 90% 5445 -
# 4 Short offline Completed without error 00% 5445 -
# 5 Short offline Completed without error 00% 5445 -
[root@ballen www]# /usr/sbin/smartctl -am /dev/hda
smartctl version 5.0-25 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: HITACHI_DK23BA-20
Serial Number: 12H7M8
Firmware Version: 00E0A0D2
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (1530) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 26) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000d 100 083 050 Pre-fail - 677
3 Spin_Up_Time 0x0007 100 100 050 Pre-fail - 0
4 Start_Stop_Count 0x0032 100 100 050 Old_age - 249
5 Reallocated_Sector_Ct 0x0033 099 099 010 Pre-fail - 30
7 Seek_Error_Rate 0x000f 100 100 050 Pre-fail - 319
9 Power_On_Hours 0x0032 099 099 060 Old_age - 701 h + 42 m
10 Spin_Retry_Count 0x0013 100 100 050 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 050 Old_age - 249
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 15
195 Hardware_ECC_Recovered 0x001a 100 001 050 Old_age In_the_past 559
196 Reallocated_Event_Count 0x0032 097 097 001 Old_age - 30
197 Current_Pending_Sector 0x0032 095 095 001 Old_age - 5
198 Offline_Uncorrectable 0x0010 095 095 001 Old_age - 31
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age - 0
221 G-Sense_Error_Rate 0x000a 100 100 050 Old_age - 0
223 Load_Retry_Count 0x0012 100 100 050 Old_age - 0
225 Load_Cycle_Count 0x0032 095 095 050 Old_age - 18446744072753281791
230 Unknown_Attribute 0x0032 100 100 060 Old_age - 18484
250 Unknown_Attribute 0x000a 100 070 050 Old_age - 601
SMART Error Log Version: 1
ATA Error Count: 9 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 458 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER:40 SC:01 SN:15 CL:be CH:2e D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 00 01 15 be 2e e0 c8 831.599
00 00 01 14 be 2e e0 c8 831.594
00 00 01 13 be 2e e0 c8 831.594
00 00 01 12 be 2e e0 c8 831.594
00 00 01 11 be 2e e0 c8 831.594
Error 2 occurred at disk power-on lifetime: 458 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER:40 SC:45 SN:15 CL:be CH:2e D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 00 80 da bd 2e e0 c8 829.680
00 00 80 5a bd 2e e0 c8 829.677
00 00 80 da bc 2e e0 c8 829.673
00 00 80 5a bc 2e e0 c8 829.671
00 00 01 58 bc 2e e0 c8 829.671
Error 3 occurred at disk power-on lifetime: 458 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER:40 SC:01 SN:47 CL:bc CH:2e D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 00 01 47 bc 2e e0 c8 826.962
00 00 01 46 bc 2e e0 c8 826.961
00 00 01 45 bc 2e e0 c8 826.961
00 00 01 44 bc 2e e0 c8 826.961
00 00 01 43 bc 2e e0 c8 826.961
Error 4 occurred at disk power-on lifetime: 458 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER:40 SC:13 SN:47 CL:bc CH:2e D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 00 80 da bb 2e e0 c8 825.038
00 00 80 5a bb 2e e0 c8 825.033
00 00 80 da ba 2e e0 c8 825.030
00 00 80 5a ba 2e e0 c8 824.940
00 00 80 da b9 2e e0 c8 824.937
Error 5 occurred at disk power-on lifetime: 458 hours
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER:40 SC:01 SN:85 CL:19 CH:2c D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 00 01 85 19 2c e0 c8 816.487
00 00 01 84 19 2c e0 c8 816.487
00 00 01 83 19 2c e0 c8 816.486
00 00 01 82 19 2c e0 c8 816.486
00 00 01 81 19 2c e0 c8 816.486
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed 00% 691
# 2 Extended off-line Completed: read failure 40% 661 0x002c1985
# 3 Extended off-line Completed: read failure 40% 661 0x002c1985
# 4 Short off-line Completed 00% 660
# 5 Extended off-line Completed: read failure 40% 658 0x002c1985
# 6 Short off-line Completed 00% 658
# 7 Short off-line Completed 00% 658
# 8 Extended off-line Completed: read failure 40% 658 0x002c1985
# 9 Extended off-line Completed: read failure 40% 657 0x002c1985
#10 Short off-line Completed 00% 647
#11 Short off-line Completed 00% 587
#12 Short off-line Completed 00% 583
#13 Short off-line Completed 00% 551
#14 Short captive Interrupted (host reset) 40% 551
#15 Short off-line Completed 00% 551
#16 Extended off-line Completed: read failure 40% 550 0x002c1985
#17 Extended off-line Aborted by host 50% 550
#18 Short off-line Completed 00% 550
#19 Short off-line Completed 00% 537
#20 Extended off-line Completed: read failure 40% 536 0x002c1985
#21 Short off-line Completed 00% 536
# smartctl -a /dev/hda
smartctl version 5.0-45 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVV207-0
Serial Number: VNVD02G4G4BDEG
Firmware Version: V24OA63A
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 3a
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (2855) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0007 102 102 024 Pre-fail - 16974103
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 14
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age - 242
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 14
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 24
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 24
194 Temperature_Celsius 0x0002 203 203 000 Old_age - 27 (Lifetime Min/Max 20/37)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 54
smartctl version 5.31 Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVV207-1
Serial Number: VNVD09G4H3HPMT
Firmware Version: V24OA66A
Device is: In smartctl database [for details use: -P show]
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 3a
Local Time is: Tue Jun 15 23:38:56 2004 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (2855) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 089 089 060 Pre-fail Always - 1703986
2 Throughput_Performance 0x0005 015 015 050 Pre-fail Offline FAILING_NOW 5518
3 Spin_Up_Time 0x0007 100 100 024 Pre-fail Always - 278
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 9
5 Reallocated_Sector_Ct 0x0033 091 091 005 Pre-fail Always - 277
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 123 123 020 Pre-fail Offline - 37
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 2759
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 45
193 Load_Cycle_Count 0x0012 100 100 050 Old_age Always - 45
194 Temperature_Celsius 0x0002 166 166 000 Old_age Always - 33 (Lifetime Min/Max 23/44)
196 Reallocated_Event_Count 0x0032 092 092 000 Old_age Always - 319
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 49
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 20
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 161 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 161 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 46 c2 a7 02 e0 Error: UNC 70 sectors at LBA = 0x0002a7c2 = 174018
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 46 c2 a7 02 e0 00 23d+03:19:20.800 READ DMA EXT
25 00 48 c0 a7 02 e0 00 23d+03:19:16.000 READ DMA EXT
25 00 1c a4 a7 02 e0 00 23d+03:19:15.200 READ DMA EXT
25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT
25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT
Error 160 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 47 c1 a7 02 e0 Error: UNC 71 sectors at LBA = 0x0002a7c1 = 174017
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 48 c0 a7 02 e0 00 23d+03:19:16.000 READ DMA EXT
25 00 1c a4 a7 02 e0 00 23d+03:19:15.200 READ DMA EXT
25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT
25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT
25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT
Error 159 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 02 be a7 02 e0 Error: UNC 2 sectors at LBA = 0x0002a7be = 174014
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT
25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT
25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT
25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT
25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT
Error 158 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 02 be a7 02 e0 Error: UNC 2 sectors at LBA = 0x0002a7be = 174014
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT
25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT
25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT
25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT
25 00 28 98 a7 02 e0 00 23d+03:18:32.100 READ DMA EXT
Error 157 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 03 bd a7 02 e0 Error: UNC 3 sectors at LBA = 0x0002a7bd = 174013
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT
25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT
25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT
25 00 28 98 a7 02 e0 00 23d+03:18:32.100 READ DMA EXT
25 00 2a 96 a7 02 e0 00 23d+03:18:26.400 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 2692 173893
# 2 Short offline Completed: read failure 10% 2654 173911
# 3 Extended offline Completed: read failure 90% 2524 174132
# 4 Extended offline Completed without error 00% 2358 -
# 5 Extended offline Completed without error 00% 2192 -
# 6 Extended offline Completed without error 00% 2023 -
# 7 Extended offline Completed without error 00% 1857 -
# 8 Extended offline Completed without error 00% 1689 -
# 9 Extended offline Completed without error 00% 1521 -
#10 Extended offline Completed without error 00% 1355 -
#11 Extended offline Completed without error 00% 1187 -
#12 Extended offline Completed without error 00% 1020 -
#13 Extended offline Completed without error 00% 854 -
#14 Extended offline Completed without error 00% 685 -
#15 Extended offline Completed without error 00% 517 -
#16 Extended offline Completed without error 00% 349 -
#17 Extended offline Completed without error 00% 181 -
#18 Extended offline Completed without error 00% 13 -
#19 Extended offline Completed without error 00% 4 -
Device does not support Selective Self Tests/Logging
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVVA07-0
Serial Number: VNC605A6GG8W8A
Firmware Version: VA6OA52A
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (3399) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 147 147 050 Pre-fail - 266
3 Spin_Up_Time 0x0007 093 093 024 Pre-fail - 23593335
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 138 138 020 Pre-fail - 30
9 Power_On_Hours 0x0012 100 100 000 Old_age - 554
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 13
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 36
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 36
194 Temperature_Centigrade 0x0002 183 183 000 Old_age - 30 (Lifetime Min/Max 23/39)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 492
# 2 Short off-line Completed 00% 296
# 3 Extended off-line Completed 00% 169
# 4 Short off-line Completed 00% 168
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVVA07-0
Serial Number: VNC605A6GEWZDA
Firmware Version: VA6OA52A
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (3399) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0007 098 098 024 Pre-fail - 22348126
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age - 554
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 13
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 36
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 36
194 Temperature_Centigrade 0x0002 189 189 000 Old_age - 29 (Lifetime Min/Max 23/36)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 492
# 2 Extended off-line Completed 00% 169
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674205306226
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x02) Offline data collection activity
completed without error.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 077 077 020 Pre-fail - 2909
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 29
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 1
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 097 097 001 Old_age - 1992
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 29
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 093 090 042 Old_age - 19
195 Hardware_ECC_Recovered 0x001a 100 006 000 Old_age - 7683906
196 Reallocated_Event_Count 0x0010 099 099 020 Old_age - 1
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 1
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 198 198 000 Old_age - 2
SMART Error Log Version: 1
ATA Error Count: 11 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:02 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 02 41 2d 70 e8 c4 90.713
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
Error 2 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:04 SN:3f CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
Error 3 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:06 SN:3d CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
Error 4 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:08 SN:3b CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
28 08 08 cb 2b 28 e8 c5 78.337
Error 5 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:66 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 66 41 2d 70 e8 c4 69.020
70 08 68 3f 2d 70 e8 c4 64.956
70 08 6a 3d 2d 70 e8 c4 60.891
70 08 6c 3b 2d 70 e8 c4 56.826
70 08 fe a9 2c 70 e8 c4 52.713
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed: read failure 90% 1965 0x08702f11
# 2 Short off-line Completed 00% 1800
# 3 Short off-line Completed 00% 1778
# 4 Short off-line Completed 00% 1777
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119123435
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x04) Offline data collection activity was
suspended by an interrupting command from host.
Self-test execution status: ( 89) The previous self-test completed having
the electrical element of the test
failed.
Total time to complete off-line
data collection: (2536) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 074 074 020 Pre-fail - 3294
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 32
5 Reallocated_Sector_Ct 0x0033 001 001 020 Pre-fail FAILING_NOW 499
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
9 Power_On_Hours 0x0012 086 086 001 Old_age - 9812
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 32
13 Read_Soft_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
194 Temperature_Centigrade 0x0022 091 086 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 006 004 000 Old_age - 417912090
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 033 032 020 Old_age - 338
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 20255 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:b8 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 60 b8 c6 02 e5 c4 474.857
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
Error 2 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:68 SN:b0 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
02 05 f8 20 c4 02 e5 c4 470.717
Error 3 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:08 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 08 c0 3e 0e e5 c4 181.677
d0 04 08 b0 67 d0 e4 c5 181.651
0e 05 08 a0 45 0e e5 c4 181.646
0e 05 80 20 43 0e e5 c4 181.635
0e 05 80 20 41 0e e5 c4 181.622
Error 4 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 80 a0 3e 0e e5 c4 172.530
0e 05 80 20 3d 0e e5 c4 172.335
0e 05 80 20 3c 0e e5 c4 164.744
0e 05 10 10 3b 0e e5 c4 164.736
0e 05 f8 18 3a 0e e5 c4 157.202
Error 5 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:c0 SN:18 CL:04 CH:d3 D/H:e4 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
d3 04 c0 18 04 d3 e4 c4 502.837
d3 04 f8 e0 03 d3 e4 c4 498.739
d3 04 f8 e8 02 d3 e4 c4 498.716
55 01 c8 90 70 55 e1 c4 498.705
55 01 38 48 70 55 e1 c4 498.680
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed: electrical failure 90% 9786
# 2 Extended captive Completed: servo/seek failure 90% 9676 0x04b7ed3d
# 3 Extended captive Completed 00% 9575
# 4 Extended off-line Completed 00% 9432
# 5 Extended off-line Completed 00% 9415
smartctl version 5.22 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119014987
Firmware Version: A08.1500
Device is: In smartctl database [for details use: -P show]
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
Local Time is: Mon Oct 27 14:30:17 2003 CST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity was
never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0
3 Spin_Up_Time 0x0027 075 074 020 Pre-fail Always - 3135
4 Start_Stop_Count 0x0032 100 100 008 Old_age Always - 54
5 Reallocated_Sector_Ct 0x0033 098 097 020 Pre-fail Always - 14
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0
9 Power_On_Hours 0x0012 072 072 001 Old_age Always - 18875
10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age Always - 53
13 Read_Soft_Error_Rate 0x000b 100 085 023 Pre-fail Always - 0
194 Temperature_Celsius 0x0022 093 088 042 Old_age Always - 20
195 Hardware_ECC_Recovered 0x001a 028 002 000 Old_age Always - 1472864733
196 Reallocated_Event_Count 0x0010 100 099 020 Old_age Offline - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age Always - 2
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 28 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Timestamp = decimal seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 28 occurred at disk power-on lifetime: 18785 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 38 ce 8f 40 e0 Error: UNC
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 38 ce 8f 40 e0 40 315.769 READ DMA
c8 00 40 c6 8f 40 e0 40 311.634 READ DMA
b0 00 01 01 4f c2 e0 1f 284.485 [Reserved SMART command]
b0 00 01 06 4f c2 e0 34 284.470 [Reserved SMART command]
b0 00 01 00 4f c2 e0 34 284.399 [Reserved SMART command]
Error 27 occurred at disk power-on lifetime: 18785 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 38 ce 8f 40 e0 Error: UNC
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 40 c6 8f 40 e0 40 311.634 READ DMA
b0 00 01 01 4f c2 e0 1f 284.485 [Reserved SMART command]
b0 00 01 06 4f c2 e0 34 284.470 [Reserved SMART command]
b0 00 01 00 4f c2 e0 34 284.399 [Reserved SMART command]
b0 00 00 00 4f c2 00 34 284.328 [Reserved SMART command]
Error 26 occurred at disk power-on lifetime: 18744 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 d1 08 bf 00 30 e0 Error: UNC
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 00 08 bf 00 30 e0 30 134.258 READ DMA
c8 00 08 cf 3d 34 e0 34 134.247 READ DMA
c8 00 08 af 00 34 e0 34 134.215 READ DMA
c8 00 28 6f 3e 28 e0 28 134.213 READ DMA
c8 00 08 67 3e 28 e0 28 134.201 READ DMA
Error 25 occurred at disk power-on lifetime: 18619 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 07 89 67 10 e3 Error: UNC
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 03 08 88 67 10 e3 10 54.493 READ DMA
c8 03 08 88 69 08 e3 08 54.483 READ DMA
c8 03 08 88 67 08 e3 08 54.471 READ DMA
c8 02 08 88 69 ec e2 ec 54.464 READ DMA
c8 02 08 88 67 ec e2 ec 54.439 READ DMA
Error 24 occurred at disk power-on lifetime: 18619 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 59 06 8a 67 0c e2 Error: UNC
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Timestamp Command/Feature_Name
-- -- -- -- -- -- -- -- --------- --------------------
c8 02 08 88 67 0c e2 0c 49.281 READ DMA
c8 02 08 88 69 08 e2 08 49.270 READ DMA
c8 02 08 88 69 04 e2 04 49.259 READ DMA
c8 02 08 88 69 00 e2 00 49.257 READ DMA
c8 02 08 50 5c 00 e2 00 49.254 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 80% 18841 0x001f807f
# 2 Extended offline Completed: read failure 80% 18673 0x020c678a
# 3 Extended offline Completed: read failure 80% 18505 0x020c678a
# 4 Extended offline Completed: read failure 80% 18338 0x020c678a
# 5 Extended offline Completed: read failure 90% 18229 0x00408f96
# 6 Extended offline Completed: read failure 80% 18171 0x02386789
# 7 Extended offline Completed without error 00% 18051 -
# 8 Short offline Completed without error 00% 18051 -
# 9 Extended offline Completed without error 00% 18003 -
#10 Extended offline Completed without error 00% 17836 -
#11 Extended offline Completed without error 00% 17668 -
#12 Extended offline Completed without error 00% 17501 -
#13 Extended offline Completed without error 00% 17334 -
#14 Extended offline Completed without error 00% 17166 -
#15 Extended offline Completed without error 00% 16999 -
#16 Extended offline Completed without error 00% 16831 -
#17 Extended offline Completed without error 00% 16664 -
#18 Extended offline Completed without error 00% 16603 -
#19 Extended offline Completed without error 00% 16497 -
#20 Extended offline Completed without error 00% 16329 -
#21 Extended offline Completed without error 00% 16163 -
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119113862
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Off-line data collection status: (0x05) Offline data collection activity was
aborted by an interrupting command from host.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 075 075 020 Pre-fail - 3249
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 31
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
9 Power_On_Hours 0x0012 086 086 001 Old_age - 9754
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 31
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 035 032 042 Old_age FAILING_NOW 168
195 Hardware_ECC_Recovered 0x001a 100 002 000 Old_age - 880099716
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed 00% 9691
# 2 Short captive Completed 00% 9691
# 3 Extended captive Completed 00% 9618
# 4 Extended captive Interrupted (host reset) 90% 9563
# 5 Short captive Completed 00% 9563
# 6 Short off-line Completed 00% 9563
# 7 Short captive Completed 00% 9545
# 8 Extended off-line Completed 00% 9541
# 9 Short captive Completed 00% 9541
#10 Extended off-line Completed 00% 9537
#11 Extended off-line Completed 00% 9536
#12 Extended off-line Interrupted (host reset) 90% 9534
#13 Extended off-line Completed 00% 9517
#14 Extended off-line Completed 00% 9484
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 6L080J4
Serial Number: 664201100034
Firmware Version: A93.0500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 35) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 40) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 069 066 020 Pre-fail - 3984
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 110
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 099 099 001 Old_age - 1294
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 110
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 092 087 042 Old_age - 22
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age - 1163
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 1038
# 2 Extended off-line Aborted by host 00% 786
# 3 Extended off-line Aborted by host 00% 786
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 6L080J4
Serial Number: 664205757172
Firmware Version: A93.0500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x04) Offline data collection activity was
suspended by an interrupting command from host.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 35) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 40) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 065 064 020 Pre-fail - 4481
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 81
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 098 098 001 Old_age - 1767
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 81
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 091 084 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age - 52795
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 1283
# /usr/sbin/smartctl -a -m /dev/hda
smartctl version 5.0-49 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: Maxtor 4R080J0
Serial Number: R20BZ3LE
Firmware Version: RAMB1TU0
ATA Version is: 7
ATA Standard is: Unrecognized. Minor revision code: 0x1e
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x82) Offline data collection activity
completed without error.
Self-test execution status: ( 33) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete off-line
data collection: ( 241) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 41) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0027 252 252 063 Pre-fail - 1621
4 Start_Stop_Count 0x0032 253 253 000 Old_age - 18
5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail - 0
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail - 0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age - 0
8 Seek_Time_Performance 0x0027 252 244 187 Pre-fail - 41642
9 Power_On_Hours 0x0032 253 253 000 Old_age - 27 h + 13 m
10 Spin_Retry_Count 0x002b 252 252 157 Pre-fail - 0
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail - 0
12 Power_Cycle_Count 0x0032 253 253 000 Old_age - 24
192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age - 0
193 Load_Cycle_Count 0x0032 253 253 000 Old_age - 0
194 Temperature_Celsius 0x0032 253 253 000 Old_age - 29
195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age - 31004
196 Reallocated_Event_Count 0x0008 253 253 000 Old_age - 0
197 Current_Pending_Sector 0x0008 253 253 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 253 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age - 0
200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age - 0
201 Unknown_Attribute 0x000a 253 252 000 Old_age - 3
202 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
203 Unknown_Attribute 0x000b 253 252 180 Pre-fail - 2
204 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
205 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
207 Unknown_Attribute 0x002a 252 252 000 Old_age - 0
208 Unknown_Attribute 0x002a 252 252 000 Old_age - 0
209 Unknown_Attribute 0x0024 079 063 000 Old_age - 0
99 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
100 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
101 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 5
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 5 occurred at disk power-on lifetime: 4 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:00 SN:00 CL:f4 CH:2c D/H:00 ST:01
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e d4 00 82 4f c2 f0 b0 8907.296
08 d4 00 82 4f c2 f0 b0 6260.832
08 d1 01 01 4f c2 f0 b0 6260.800
08 d0 01 00 4f c2 f0 b0 6260.768
08 da 00 00 4f c2 10 b0 6260.736
Error 4 occurred at disk power-on lifetime: 1 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:00 SN:00 CL:f4 CH:2c D/H:00 ST:01
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e d4 00 82 4f c2 f0 b0 1944.192
08 d4 00 82 4f c2 f0 b0 1824.240
08 d1 01 01 4f c2 f0 b0 1824.224
08 d0 01 00 4f c2 f0 b0 1824.160
08 00 08 3f 00 00 f0 ca 1810.400
Error 3 occurred at disk power-on lifetime: 1 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:00 SN:00 CL:f4 CH:2c D/H:00 ST:01
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e d4 00 82 4f c2 f0 b0 1456.432
08 d4 00 82 4f c2 f0 b0 1379.456
08 d1 01 01 4f c2 f0 b0 1379.440
08 d0 01 00 4f c2 f0 b0 1379.376
08 00 08 f7 01 54 f0 ca 1378.544
Error 2 occurred at disk power-on lifetime: 0 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:00 SN:00 CL:f4 CH:2c D/H:00 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
08 d4 00 82 4f c2 f0 b0 908.320
08 d1 01 01 4f c2 f0 b0 908.320
08 d0 01 00 4f c2 f0 b0 908.272
08 d4 00 7f 4f c2 f0 b0 905.696
08 d1 01 01 4f c2 f0 b0 905.664
Error 1 occurred at disk power-on lifetime: 0 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:50 SN:40 CL:97 CH:03 D/H:10 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 fe 00 00 00 00 10 ef 137.184
00 3d 00 00 00 00 10 c3 137.136
00 e4 00 00 00 00 10 c3 137.088
00 3d 00 00 00 00 10 c3 137.088
00 00 00 00 5e 20 10 70 137.040
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended captive Interrupted (host reset) 10% 4
# 2 Short off-line Completed 00% 2
# 3 Short captive Completed 00% 2
# 4 Extended captive Interrupted (host reset) 40% 1
# 5 Extended captive Interrupted (host reset) 70% 1
# 6 Extended captive Interrupted (host reset) 40% 0
smartctl version 5.1-4 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119114160
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
Local Time is: Tue May 13 08:59:49 2003 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x82) Offline data collection activity
completed without error.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 075 075 020 Pre-fail - 3214
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 58
5 Reallocated_Sector_Ct 0x0033 098 098 020 Pre-fail - 12
7 Seek_Error_Rate 0x000b 001 001 023 Pre-fail FAILING_NOW 13
9 Power_On_Hours 0x0012 078 078 001 Old_age - 14851
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 090 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 58
13 Read_Soft_Error_Rate 0x000b 100 085 023 Pre-fail - 0
194 Temperature_Celsius 0x0022 091 087 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 004 003 000 Old_age - 513691822
196 Reallocated_Event_Count 0x0010 099 099 020 Old_age - 1
197 Current_Pending_Sector 0x0032 098 098 020 Old_age - 12
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 25 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 25 occurred at disk power-on lifetime: 14799 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:04 SN:53 CL:1d CH:0c D/H:e0 ST:59
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0c 00 08 4f 1d 0c e0 c8 0.523
0c 00 08 47 1d 0c e0 c8 510.677
04 00 08 6f 04 04 e0 ca 510.675
04 00 08 4f 1c 04 e0 ca 510.674
04 00 08 6f 04 04 e0 ca 510.674
Error 24 occurred at disk power-on lifetime: 14799 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:03 SN:44 CL:1d CH:0c D/H:e0 ST:59
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0c 00 08 3f 1d 0c e0 c8 495.294
0c 00 08 37 1d 0c e0 c8 491.239
0c 00 08 2f 1d 0c e0 c8 488.433
14 00 08 17 04 14 e0 ca 488.432
0c 00 08 b7 00 0c e0 ca 488.432
Error 23 occurred at disk power-on lifetime: 14799 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:06 SN:21 CL:18 CH:0c D/H:e0 ST:59
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0c 00 08 1f 18 0c e0 c8 392.659
00 00 08 17 18 0c e0 c8 392.654
0c 00 08 0f 18 0c e0 c8 392.624
00 00 08 07 18 0c e0 c8 392.620
00 00 08 ff 17 0c e0 c8 392.615
Error 22 occurred at disk power-on lifetime: 14799 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:05 SN:b2 CL:16 CH:0c D/H:e0 ST:59
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0c 00 08 af 16 0c e0 c8 385.889
04 00 08 6f 04 04 e0 ca 385.886
04 00 08 4f 1c 04 e0 ca 385.886
04 00 08 6f 04 04 e0 ca 385.886
04 00 08 4f 1c 04 e0 ca 385.885
Error 21 occurred at disk power-on lifetime: 14799 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:06 SN:a9 CL:16 CH:0c D/H:e0 ST:59
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0c 00 08 a7 16 0c e0 c8 381.795
04 00 08 6f 04 04 e0 ca 381.793
04 00 08 4f 1c 04 e0 ca 381.793
04 00 08 6f 04 04 e0 ca 381.792
04 00 08 4f 1c 04 e0 ca 381.792
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed: read failure 90% 14757 0x000409bb
# 2 Extended off-line Completed: read failure 90% 14755 0x000bf956
# 3 Extended off-line Completed 00% 14305 -
# 4 Extended off-line Completed 00% 14100 -
# 5 Extended off-line Completed 00% 13721 -
# 6 Extended off-line Completed 00% 13636 -
# 7 Extended off-line Completed 00% 13233 -
# 8 Extended off-line Completed 00% 13078 -
# 9 Extended off-line Completed 00% 12093 -
#10 Extended off-line Completed 00% 11926 -
#11 Extended off-line Completed 00% 11428 -
#12 Extended off-line Completed 00% 11030 -
#13 Extended off-line Completed 00% 10888 -
#14 Extended off-line Completed 00% 10728 -
#15 Extended off-line Completed 00% 10435 -
#16 Extended off-line Completed 00% 10267 -
#17 Extended off-line Completed 00% 10098 -
#18 Extended off-line Completed 00% 9930 -
#19 Extended off-line Completed 00% 9599 -
smartctl version 5.1-14 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119116076
Firmware Version: A08.1500
Device is: In smartctl database [for details use: -P show]
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
Local Time is: Tue Jun 17 14:46:37 2003 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x82) Offline data collection activity was
completed without error.
Auto Off-line Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0
3 Spin_Up_Time 0x0027 075 075 020 Pre-fail Always - 3249
4 Start_Stop_Count 0x0032 100 100 008 Old_age Always - 45
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail Always In_the_past 0
9 Power_On_Hours 0x0012 082 082 001 Old_age Always - 12223
10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0013 020 020 020 Pre-fail Always FAILING_NOW 8
12 Power_Cycle_Count 0x0032 100 100 008 Old_age Always - 45
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0
194 Temperature_Celsius 0x0022 094 088 042 Old_age Always - 17
195 Hardware_ECC_Recovered 0x001a 100 007 000 Old_age Always - 494134044
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age Offline - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 11610 -
# 2 Extended off-line Completed 00% 11213 -
# 3 Extended off-line Completed 00% 11072 -
# 4 Extended off-line Completed 00% 10911 -
# 5 Extended off-line Completed 00% 10618 -
# 6 Extended off-line Completed 00% 10450 -
# 7 Extended off-line Completed 00% 10282 -
# 8 Extended off-line Completed 00% 10114 -
# 9 Extended off-line Completed 00% 9783 -
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment