# smartctl -a /dev/hda
smartctl version 5.0-45 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVV207-0
Serial Number: VNVD02G4G4BDEG
Firmware Version: V24OA63A
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 3a
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (2855) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0007 102 102 024 Pre-fail - 16974103
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 14
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age - 242
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 14
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 24
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 24
194 Temperature_Celsius 0x0002 203 203 000 Old_age - 27 (Lifetime Min/Max 20/37)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 54
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVVA07-0
Serial Number: VNC605A6GG8W8A
Firmware Version: VA6OA52A
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (3399) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 147 147 050 Pre-fail - 266
3 Spin_Up_Time 0x0007 093 093 024 Pre-fail - 23593335
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 138 138 020 Pre-fail - 30
9 Power_On_Hours 0x0012 100 100 000 Old_age - 554
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 13
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 36
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 36
194 Temperature_Centigrade 0x0002 183 183 000 Old_age - 30 (Lifetime Min/Max 23/39)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 492
# 2 Short off-line Completed 00% 296
# 3 Extended off-line Completed 00% 169
# 4 Short off-line Completed 00% 168
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVVA07-0
Serial Number: VNC605A6GEWZDA
Firmware Version: VA6OA52A
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (3399) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0007 098 098 024 Pre-fail - 22348126
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age - 554
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 13
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 36
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 36
194 Temperature_Centigrade 0x0002 189 189 000 Old_age - 29 (Lifetime Min/Max 23/36)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 492
# 2 Extended off-line Completed 00% 169
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674205306226
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x02) Offline data collection activity
completed without error.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 077 077 020 Pre-fail - 2909
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 29
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 1
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 097 097 001 Old_age - 1992
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 29
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 093 090 042 Old_age - 19
195 Hardware_ECC_Recovered 0x001a 100 006 000 Old_age - 7683906
196 Reallocated_Event_Count 0x0010 099 099 020 Old_age - 1
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 1
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 198 198 000 Old_age - 2
SMART Error Log Version: 1
ATA Error Count: 11 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:02 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 02 41 2d 70 e8 c4 90.713
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
Error 2 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:04 SN:3f CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
Error 3 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:06 SN:3d CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
Error 4 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:08 SN:3b CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
28 08 08 cb 2b 28 e8 c5 78.337
Error 5 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:66 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 66 41 2d 70 e8 c4 69.020
70 08 68 3f 2d 70 e8 c4 64.956
70 08 6a 3d 2d 70 e8 c4 60.891
70 08 6c 3b 2d 70 e8 c4 56.826
70 08 fe a9 2c 70 e8 c4 52.713
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed: read failure 90% 1965 0x08702f11
# 2 Short off-line Completed 00% 1800
# 3 Short off-line Completed 00% 1778
# 4 Short off-line Completed 00% 1777
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119123435
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x04) Offline data collection activity was
suspended by an interrupting command from host.
Self-test execution status: ( 89) The previous self-test completed having
the electrical element of the test
failed.
Total time to complete off-line
data collection: (2536) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 074 074 020 Pre-fail - 3294
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 32
5 Reallocated_Sector_Ct 0x0033 001 001 020 Pre-fail FAILING_NOW 499
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
9 Power_On_Hours 0x0012 086 086 001 Old_age - 9812
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 32
13 Read_Soft_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
194 Temperature_Centigrade 0x0022 091 086 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 006 004 000 Old_age - 417912090
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 033 032 020 Old_age - 338
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 20255 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:b8 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 60 b8 c6 02 e5 c4 474.857
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
Error 2 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:68 SN:b0 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
02 05 f8 20 c4 02 e5 c4 470.717
Error 3 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:08 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 08 c0 3e 0e e5 c4 181.677
d0 04 08 b0 67 d0 e4 c5 181.651
0e 05 08 a0 45 0e e5 c4 181.646
0e 05 80 20 43 0e e5 c4 181.635
0e 05 80 20 41 0e e5 c4 181.622
Error 4 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 80 a0 3e 0e e5 c4 172.530
0e 05 80 20 3d 0e e5 c4 172.335
0e 05 80 20 3c 0e e5 c4 164.744
0e 05 10 10 3b 0e e5 c4 164.736
0e 05 f8 18 3a 0e e5 c4 157.202
Error 5 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:c0 SN:18 CL:04 CH:d3 D/H:e4 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
d3 04 c0 18 04 d3 e4 c4 502.837
d3 04 f8 e0 03 d3 e4 c4 498.739
d3 04 f8 e8 02 d3 e4 c4 498.716
55 01 c8 90 70 55 e1 c4 498.705
55 01 38 48 70 55 e1 c4 498.680
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed: electrical failure 90% 9786
# 2 Extended captive Completed: servo/seek failure 90% 9676 0x04b7ed3d
# 3 Extended captive Completed 00% 9575
# 4 Extended off-line Completed 00% 9432
# 5 Extended off-line Completed 00% 9415
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment