smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: IC35L120AVVA07-0
Serial Number: VNC605A6GEWZDA
Firmware Version: VA6OA52A
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: (3399) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 57) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 060 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0007 098 098 024 Pre-fail - 22348126
4 Start_Stop_Count 0x0012 100 100 000 Old_age - 13
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age - 554
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 13
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age - 36
193 Load_Cycle_Count 0x0012 100 100 050 Old_age - 36
194 Temperature_Centigrade 0x0002 189 189 000 Old_age - 29 (Lifetime Min/Max 23/36)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 492
# 2 Extended off-line Completed 00% 169
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674205306226
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x02) Offline data collection activity
completed without error.
Self-test execution status: ( 112) The previous self-test completed having
the read element of the test failed.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 077 077 020 Pre-fail - 2909
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 29
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 1
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 097 097 001 Old_age - 1992
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 29
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 093 090 042 Old_age - 19
195 Hardware_ECC_Recovered 0x001a 100 006 000 Old_age - 7683906
196 Reallocated_Event_Count 0x0010 099 099 020 Old_age - 1
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 1
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 198 198 000 Old_age - 2
SMART Error Log Version: 1
ATA Error Count: 11 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:02 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 02 41 2d 70 e8 c4 90.713
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
Error 2 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:04 SN:3f CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 04 3f 2d 70 e8 c4 86.648
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
Error 3 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:06 SN:3d CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 06 3d 2d 70 e8 c4 82.584
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
Error 4 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:08 SN:3b CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 08 3b 2d 70 e8 c4 78.342
28 08 04 8b 2c 28 e8 c5 78.341
28 08 08 4b 2c 28 e8 c5 78.339
28 08 08 0b 2c 28 e8 c5 78.338
28 08 08 cb 2b 28 e8 c5 78.337
Error 5 occurred at disk power-on lifetime: 1029 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:40 SC:66 SN:41 CL:2d CH:70 D/H:e8 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
70 08 66 41 2d 70 e8 c4 69.020
70 08 68 3f 2d 70 e8 c4 64.956
70 08 6a 3d 2d 70 e8 c4 60.891
70 08 6c 3b 2d 70 e8 c4 56.826
70 08 fe a9 2c 70 e8 c4 52.713
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed: read failure 90% 1965 0x08702f11
# 2 Short off-line Completed 00% 1800
# 3 Short off-line Completed 00% 1778
# 4 Short off-line Completed 00% 1777
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119123435
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Off-line data collection status: (0x04) Offline data collection activity was
suspended by an interrupting command from host.
Self-test execution status: ( 89) The previous self-test completed having
the electrical element of the test
failed.
Total time to complete off-line
data collection: (2536) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 074 074 020 Pre-fail - 3294
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 32
5 Reallocated_Sector_Ct 0x0033 001 001 020 Pre-fail FAILING_NOW 499
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
9 Power_On_Hours 0x0012 086 086 001 Old_age - 9812
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 32
13 Read_Soft_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
194 Temperature_Centigrade 0x0022 091 086 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 006 004 000 Old_age - 417912090
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 033 032 020 Old_age - 338
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 20255 (device log contains only the most recent five errors)
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:b8 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 60 b8 c6 02 e5 c4 474.857
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
Error 2 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:68 SN:b0 CL:c6 CH:02 D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
02 05 f8 20 c6 02 e5 c4 470.748
02 05 08 18 c6 02 e5 c4 470.746
00 00 f8 20 c5 02 e5 c4 470.732
00 00 08 18 c5 02 e5 c4 470.730
02 05 f8 20 c4 02 e5 c4 470.717
Error 3 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:08 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 08 c0 3e 0e e5 c4 181.677
d0 04 08 b0 67 d0 e4 c5 181.651
0e 05 08 a0 45 0e e5 c4 181.646
0e 05 80 20 43 0e e5 c4 181.635
0e 05 80 20 41 0e e5 c4 181.622
Error 4 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:60 SN:c0 CL:3e CH:0e D/H:e5 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
0e 05 80 a0 3e 0e e5 c4 172.530
0e 05 80 20 3d 0e e5 c4 172.335
0e 05 80 20 3c 0e e5 c4 164.744
0e 05 10 10 3b 0e e5 c4 164.736
0e 05 f8 18 3a 0e e5 c4 157.202
Error 5 occurred at disk power-on lifetime: 9574 hours
When the command that caused the error occurred, the device was in a vendor specific or reserved state.
After command completion occurred, registers were:
ER:40 SC:c0 SN:18 CL:04 CH:d3 D/H:e4 ST:d1
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
d3 04 c0 18 04 d3 e4 c4 502.837
d3 04 f8 e0 03 d3 e4 c4 498.739
d3 04 f8 e8 02 d3 e4 c4 498.716
55 01 c8 90 70 55 e1 c4 498.705
55 01 38 48 70 55 e1 c4 498.680
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed: electrical failure 90% 9786
# 2 Extended captive Completed: servo/seek failure 90% 9676 0x04b7ed3d
# 3 Extended captive Completed 00% 9575
# 4 Extended off-line Completed 00% 9432
# 5 Extended off-line Completed 00% 9415
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 4K080H4
Serial Number: 674119113862
Firmware Version: A08.1500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Off-line data collection status: (0x05) Offline data collection activity was
aborted by an interrupting command from host.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 44) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 50) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 075 075 020 Pre-fail - 3249
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 31
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 001 023 Pre-fail In_the_past 0
9 Power_On_Hours 0x0012 086 086 001 Old_age - 9754
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 31
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 035 032 042 Old_age FAILING_NOW 168
195 Hardware_ECC_Recovered 0x001a 100 002 000 Old_age - 880099716
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed 00% 9691
# 2 Short captive Completed 00% 9691
# 3 Extended captive Completed 00% 9618
# 4 Extended captive Interrupted (host reset) 90% 9563
# 5 Short captive Completed 00% 9563
# 6 Short off-line Completed 00% 9563
# 7 Short captive Completed 00% 9545
# 8 Extended off-line Completed 00% 9541
# 9 Short captive Completed 00% 9541
#10 Extended off-line Completed 00% 9537
#11 Extended off-line Completed 00% 9536
#12 Extended off-line Interrupted (host reset) 90% 9534
#13 Extended off-line Completed 00% 9517
#14 Extended off-line Completed 00% 9484
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 6L080J4
Serial Number: 664201100034
Firmware Version: A93.0500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 35) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 40) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 069 066 020 Pre-fail - 3984
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 110
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 099 099 001 Old_age - 1294
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 110
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 092 087 042 Old_age - 22
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age - 1163
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 1038
# 2 Extended off-line Aborted by host 00% 786
# 3 Extended off-line Aborted by host 00% 786
smartctl version 5.0-24 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: MAXTOR 6L080J4
Serial Number: 664205757172
Firmware Version: A93.0500
ATA Version is: 5
ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x04) Offline data collection activity was
suspended by an interrupting command from host.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 35) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 40) minutes.
SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail - 0
3 Spin_Up_Time 0x0027 065 064 020 Pre-fail - 4481
4 Start_Stop_Count 0x0032 100 100 008 Old_age - 81
5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail - 0
9 Power_On_Hours 0x0012 098 098 001 Old_age - 1767
10 Spin_Retry_Count 0x0026 100 100 000 Old_age - 0
11 Calibration_Retry_Count 0x0013 100 100 020 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 008 Old_age - 81
13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail - 0
194 Temperature_Centigrade 0x0022 091 084 042 Old_age - 24
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age - 52795
196 Reallocated_Event_Count 0x0010 100 100 020 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 020 Old_age - 0
198 Offline_Uncorrectable 0x0010 100 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 1283
smartctl version 5.0-36 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: Maxtor 98196H8
Serial Number: V80HV6NC
Firmware Version: ZAH814Y0
ATA Version is: 6
ATA Standard is: ATA/ATAPI-6 T13 1410D revision 0
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000a 253 252 000 Old_age - 26
3 Spin_Up_Time 0x0027 208 206 063 Pre-fail - 11285
4 Start_Stop_Count 0x0032 253 253 000 Old_age - 62
5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail - 0
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail - 0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age - 0
8 Seek_Time_Performance 0x0027 249 244 187 Pre-fail - 50271
9 Power_On_Hours 0x0032 236 236 000 Old_age - 32671
10 Spin_Retry_Count 0x002b 253 252 223 Pre-fail - 0
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail - 0
12 Power_Cycle_Count 0x0032 253 253 000 Old_age - 67
196 Reallocated_Event_Count 0x0008 253 253 000 Old_age - 0
197 Current_Pending_Sector 0x0008 253 253 000 Old_age - 0
198 Offline_Uncorrectable 0x0008 253 253 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age - 0
200 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
201 Unknown_Attribute 0x000a 253 252 000 Old_age - 1
202 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
203 Unknown_Attribute 0x000b 253 252 180 Pre-fail - 2
204 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
205 Unknown_Attribute 0x000a 253 252 000 Old_age - 0
207 Unknown_Attribute 0x002a 253 252 000 Old_age - 0
208 Unknown_Attribute 0x002a 253 252 000 Old_age - 0
209 Unknown_Attribute 0x0024 253 253 000 Old_age - 0
96 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
97 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
98 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
99 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
100 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
101 Unknown_Attribute 0x0004 253 253 000 Old_age - 0
SMART Error Log Version: 1
ATA Error Count: 3
DCR = Device Control Register
FR = Features Register
SC = Sector Count Register
SN = Sector Number Register
CL = Cylinder Low Register
CH = Cylinder High Register
D/H = Device/Head Register
CR = Content written to Command Register
ER = Error register
STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.
Error 1 occurred at disk power-on lifetime: 0 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:40 SN:42 CL:97 CH:23 D/H:00 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 fe 00 00 00 00 00 ef 137.440
00 d9 00 00 4f c2 00 b0 137.328
00 da 00 00 4f c2 00 b0 137.232
00 d8 00 00 4f c2 00 b0 137.152
00 db 00 00 4f c2 00 b0 136.976
Error 2 occurred at disk power-on lifetime: 0 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:40 SN:40 CL:97 CH:23 D/H:00 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 fe 00 00 00 00 00 ef 342.432
00 e4 00 00 00 00 00 c3 342.368
00 d0 00 00 0a 00 00 c3 342.368
00 fe 00 00 00 00 00 ef 342.304
00 3d 00 00 00 00 00 c3 342.256
Error 3 occurred at disk power-on lifetime: 0 hours
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER:04 SC:40 SN:40 CL:97 CH:03 D/H:00 ST:51
Sequence of commands leading to the command that caused the error were:
DCR FR SC SN CL CH D/H CR Timestamp
00 fe 00 00 00 00 00 ef 342.304
00 3d 00 00 00 00 00 c3 342.256
00 e4 00 00 00 00 00 c3 342.192
00 3d 00 00 00 00 00 c3 342.192
00 00 01 01 00 00 00 ec 342.144
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short off-line Completed 00% 5255
smartctl version 5.0-31 Copyright (C) 2002 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MK2018GAS
Serial Number: X22F7553T
Firmware Version: Q2.03 D
ATA Version is: 5
ATA Standard is: Unrecognized. Minor revision code: 0x00
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
never started.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete off-line
data collection: ( 212) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Automatic timer ON/OFF support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 23) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail - 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail - 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail - 910
4 Start_Stop_Count 0x0032 100 100 000 Old_age - 18
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail - 0
7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail - 0
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age - 9
10 Spin_Retry_Count 0x0033 100 100 030 Pre-fail - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age - 18
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age - 6
193 Load_Cycle_Count 0x0032 100 100 000 Old_age - 437
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age - 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age - 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age - 0
220 Disk_Shift 0x0002 100 100 000 Old_age - 4250
222 Loaded_Hours 0x0032 100 100 000 Old_age - 4
223 Load_Retry_Count 0x0032 100 100 000 Old_age - 0
224 Load_Friction 0x0022 100 100 000 Old_age - 0
226 Load-in_Time 0x0026 100 100 000 Old_age - 590
240 Unknown_Attribute 0x0001 100 100 001 Pre-fail - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log, version number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended off-line Completed 00% 4
# 2 Short captive Completed 00% 0
# 3 Short off-line Completed 00% 0
This diff is collapsed.
#! /bin/bash
# This is a script to wrap smartctl output into http:// displayable form
# It requires a filename as input, and produces an file with a .html extension as output
if [ $# -ne 1 ] ; then
echo This script requires one a file as input
exit 1
fi
model=`grep "Device Model" $1 | awk '{print $3}' `
# see if file name in use
let i=0
while [ -f $model-$i.html ] ; do
let i+=1
done
filename=$model-$i
echo -e "<pre><tt>\n" > $filename.html
cat $1 >> $filename.html
echo -e "</tt></pre>\n" >> $filename.html
echo created file $filename.html
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Please register or to comment